Most Strong Condenser Tube Plugs

By Kenya England


As a means of regaining stability of a chiller or a heat exchanger, plugs are put in place to remove leaky tubes out of action. This follows the rule that is a it will need to be re-tubed after eleven percent of the tubes have been put in place.All the condenser tube plugs must be plugged at both ends.

When condenser tubes leak, water supplied for cooling is drawn by the condenser vacuum into the condensate. The impact level of this impurity will depend on the level of the cooling water that is in-leakage and the quality of the cooling water. System design and boiler water treatment are selected with consideration of minimizing damage from condenser tubes leak. For these reasons, these plugs are required to prevent further damage and improve production efficiency. These include Ex-three expanding plug, The Pin plug, Fiber plugs, High confidence plugs, Tube-sheet plug and Ex-f expanding plug.

Ex-3 fitting is tried to withstand an extensive variety of weight, temperature and vibration states reaching up to 150 pounds for every square crawl. It highlights an extensive external washer that allows tubes to fit with sheets and not permit the attachment to be maneuvered into the vacuum of the unit. It is accessible in metal, bronze, stainless steel and titanium. It is additionally simple to rapidly introduce and oversee and has a larger than usual washer permitting this attachment to be put flush with the tube sheet and thus not be sucked into the tube by unit vacuum.

For perpetual sealing of condenser and tube sheets gaps, the one bit of decreased outline of the Type 1 pin Plug is machined to match particular tubes sizes. The one-piece configuration is a snap to introduce utilizing a hammer. What's more, can be welded into spot. For this sort of fitting, Special materials and sizes can be exclusively made. This kind of tubes gives a simple answer for changeless stopping for tubes or sheet gaps.

Fiber plug is easily installed for emergency and temporary plugging of the condenser and heat exchanger tubes. They expand when wet to effectively seal off the tubes. They do not damage sheets and can be used at height temperatures of two hundred and thirty Fahrenheit and pressures of up to four hundred psi. It requires only a mallet for quick and easy installation and is machined to fit specific tubes sizes.

The high confidence type of plugs are suitable to be used when leaking tubes have to be plugged off the heat exchangers so that they can be utilized. High confidence plugs features include re-usability, durability and innovative gripping and sealing design.

The sheet attachment gives a remarkable full-length seal at great temperatures and disconnects sheet openings from the framework, permitting proceeded with utilization of the unit without real update. The two piece configuration is a snap to introduce utilizing a hammer and can therefore be welded to the spot. It is accessible in bronze and steel.

The expanding plug completes the list. It has a two-action design which makes it the best choice for distinct applications where plug spillage may be of priority. Its distinct features include dual action sealing and gripping design and ease of installation.