Learn What A Type J Thermocouple Is Used For

By Claudette Lambert


With the aim of helping consumers distinguish between all the different kinds of thermocouples offered at the present time, there are charts and color code listings to assist them. Four worldwide calibrations are generally found, specifically J, K, E and T; each of which is suited for different and varying temperature ranges. When it comes to upper or surface heat recording within control apparatus the perfect solution would be to use the type j thermocouple.

More often than not the J-type range is used generally on areas where liquid immersion and exposure to air and gas are present. Furthermore, they can be adapted for use in penetration of soft solids and to measure air or surface temperatures. As with most thermocouples, these types can also be fitted within connectors of standard or miniature size.

Characteristically J-models are fabricated from the use of copper-nickel alloy and iron; their wires are set out with the negative one being copper-nickel alloys while the positive one is the iron wire. Although they are not as popular as some other thermocouples they are plentiful and a lot cheaper to purchase. The reason they are not used as often is due to their increased risk of rust and the fact that their temperature scope is relatively low; between -40 and 750 Celsius.

When it comes to the actual wiring of these couplers, it is vital that the correct wires are spliced together that match the specific type of coupler and its use. Because these wires are polarity receptive it may cause severe complications is one mixes for instance J and K type wires. Even though both of these couplers have a red negative wire, one must always remember to join like colored wires together.

Output signals found are normally within the milli- volt range with an extremely low temperature - voltage sensitivity. Therefore one will need to pay careful attention to any sources that could cause errors that impact the accuracy of the measurements. Factors that are common source of erroneous readings that should be considered are gain and offset errors, noise, thermocouple and cold-junction recompense accuracy errors.

These diminutive temperature gauges are made by the welding of two metals to one another. Forces generated by the variations in hot and cold at the fusion point creates electromotive forces. It is commonly called the Seebeck effect and is still the more popular method of measuring temperatures.

Standardized guiding principles and professional aid from expert engineers has been arranged by Transducer manufacturers. Organized configuration charts or regulations guides for explicit purposes are made available via catalogs, aimed at reducing mistakes. Codes and colors might well vary from each manufacturer so one should take caution when purchasing them.

Another area that needs careful attention is that the controllers are programmed for each individual thermo coupler to make certain that accurate temperature readings occur. Due to the fact that radical magnetic shifts could occur if exposed to high temperatures; and this will then result in an alteration of the material make-up of the component known as a recalibration. Type j thermocouple items are not recommended for any application where temperatures exceed 760 degrees Celsius.